Quiet Electronics Moderated Newsgroup For The Electronic Professionals and Other Professionals   >   Colorado   >   24A34-5 blower delay heat sequencer triple stack hvac r

24A34-5 blower delay heat sequencer triple stack hvac r


24A34-5 Blower Delay Heat Sequencer Triple Stack HVAC R
24A34-5 Triple Stack Blower Delay Heat Sequencer
The item you are looking at is Brand New. This is a Blower Delay heat sequencer used on many electric heating elements, and. should work on many different brands, such as carrier, trane, american standard, comfortmaker, heil, tempstar, arcoaire, goodman, and many others. Also know as an electric furnace sequencer.
Thermo-disc Sequencer Relays replaces White Rodgers, Honeywell & most others. Whiterodgers 24A34-5, 230v contacts 24volt control
Fan/Heat Sequencer, Off Time 40-110 Seconds, On Time 1-20 Seconds, Number of Timings 1, Number of Switches 2, Inductive Full Load Current @ 480 VAC 3 Amps, Inductive Full Load Current @ 120 VAC 10 Amps, Inductive Full Load Current @ 240 VAC 5 Amps, Locked Rotor Current @ 120 VAC 60 Amps, Locked Rotor Current @ 240 VAC 30 Amps, Locked Rotor Current @ 480 VAC 18 Amps, Contact Current Rating Resistive @ 120VAC 25 Amps, Contact Current Rating Resistive @ 240VAC 25 Amps
5. Recreational vehicle blower and element control
6. Heat pump blower and heating element control
7. Motor speed switching in air conditioning (high speed) / heating systems
(low speed) where a single set of contacts handle combination motor and heater element loading
8. Control circuits requiring definite sequence on both start up and shut down.
Special order parts information:
We have spent over 20 years in the Air Conditioning and Refrigeration industry including I.A.Q. (Indoor Air Quality). If you're looking for a specific part for a piece of equipment please don't hesitate to drop us an email at ****@klddistributorsinc.com with as much information as possible. Details like part numbers, dimensions and photos if possible will help speed up the process. We specialize in the hard to find and special order items and if we can't get it for you more then often then not we will let you know where you can find it.
We have access to many other items and if you don't see just what you need let us know and we'll be happy to list the item for you.
A new simple method for selecting and replacing
electric heat sequencers with only five basic controls.
Replace sequencers in almost any existing system.
A. Determine the number of circuits to be
switched. (Electrical rating of auxiliary switch
same as main switch.) When more than one
(1) sequencer is required the sequencers
are to be wired in series with the last switch
in each sequencer energizing the control circuit
B. Select from the chart the sequencers needed
for the number of circuits to be switched.
These sequencers may be wired in series to
allow sequencing of virtually any number of
If the sequencers control the fan/blower circuit, the first
switch (M1-M2) of each sequencer must always control
the fan. This provides a fan interlock to insure that the
fan will remain on until all elements are de-energized.
• Replaces Honeywell and White-Rodgers
• Ambient rated from 20°F. to 160°F.
• Used on both separate blower and element and combination blower and element systems
• Standard double quick-connect terminals for combination fan and element systems
• Full-load-rated auxiliary contacts
• Voltage and ambient self compensating positive temperature coefficient (PTC) heater elements
• UL and CSA listing available
Cross Reference:Supco Q105, Napco N105, Mars 33232, Watsco TDR30, Klixon 51172-32, TOD 15SH22309575, White Rodgers 24A34-5, Hughes 102768, Jepco 51172-32-2
* In the event you have a problem once you recieve your item we will do everything in our power to resolve the issue.
* Please conduct your self accordingly when contacting us about a purchase you've made.
* Phone: (***)-248-0817 Monday - Friday / From 9:00AM - 5:00PM Eastern Standard Time
* Email: ****@klddistributorsinc.com (24/7/365) All emails answered as quickly as possible.
Special Part and Bulk Requests:



24A34-5 blower delay heat sequencer triple stack hvac r